Annunciator Front View. Communicating Annunciator.  Site monitoring and alarm reporting sysetms.  Monitor remote sites for contact closures, voltage levels, environmental; temperature, humidity, power, voltage, water.  Report alarms via annunciators, visual and audible indicators, auto-dial to pagers, workstations, PCs, printers.
Annunciator Front View
Annunciator Rear View. Communicating Annunciator.  Site monitoring and alarm reporting sysetms.  Monitor remote sites for contact closures, voltage levels, environmental; temperature, humidity, power, voltage, water.  Report alarms via annunciators, visual and audible indicators, auto-dial to pagers, workstations, PCs, printers.
Annunciator Rear View
Features
  • Reports and Displays 16 Alarm or Status Inputs
  • Remote Control of 16 Independent Relays
  • Dual Communication Channels RS-232 and RS-485
  • Interfaces to PC and Remotely Controlled I/O Mod

The ultimate alarm reporting and remote control system gives you flexible and programmable monitoring of virtually any alarm condition. These communicating annunciators support alarm inputs from open or closed contacts, voltage changes, loss of data transitions, and changes in control lead status. Models are also available that can monitor for unique data streams. Sixteen independent relays form C relay contacts can be remotely controlled or used to echo alarm inputs. Alarm status of each channel is displayed by red or green LEDs. An audible buzzer and master alarm relay provides summary status for all sixteen circuits.

Annunciators can be used independently, in pairs over a communications channel for bi-directional alarm reporting, or in a polled or dial-up network.

Annunciator Attributes
Alarm Input Types Supported
Contacts (Open/Closed) · Voltage Changes · Loss of Data Transitions · Changes in Control Lead Status (RS-232, V.35) Data Stream Detection.
Selectable Levels of Optical Isolation
Choose Complete Isolation, Non-Isolated or Common Ground.
Input Qualifying Time: (De-Bounce)
Adjustable: 25 MS. to 5 Sec.
Relay Outputs
Sixteen independent form C relay contacts can be remotely controlled or uses to echo Alarm Inputs.
Local Alarm Reporting & Display Sequence
The alarm status of each of the 16 channels is displayed by Green and Red LED's and can be echoed on a form C relay. An audible buzzer and master alarm relay provide summary status of all 16 circuits.
Communication Capabilities
Two active full-time communication ports are jumper set to operate in RS-232 or RS-485 formats. The primary port can be RS-232 configured with an external or optional internal modem. In RS-485 mode ANN can communicate up to 5000 feet over one pair of wires directly without modems or other devices.
|
|
|
|
|
|
|