CALL: 201-934-9944 / 800-436-3284
Home >
Remote Reboot > Serial BootBar

Remote Control Power Strips

  1. General
  2. Operation
  3. Features
  4. Specifications
  5. Support
Serial and Relay Controlled Power Strips
 

  • Serial and Contact Closure Control
  • Multi-Outlet, Multi-User Remote Reboot
  • Outlet Grouping for Simultaneous Switching
  • Current Sensing and Alarming
  • Full Compliance - UL - CE - FCC
relay and serial controlled power strip.  sBB series rack mounted power distribution

These remote control power strips provide eight independently controllable outlets for reboot, security, energy management, stress testing, etc. System designers can easily integrate these power strips, using either simple RS-232 serial commands, or relay closures to operate each outlet.

Buy Now
 
sBB-N15
North American Version (NEMA)
$ 395.00
sBB-C10
International Version (IEC)
$ 410.00
North American and International Versions
Use either Serial Port or Contact Closures to control eight A/C Power Outlets remote control power strip. sBB Series serial and contact closure relay control

Serial Command Control


Serial iBootBar provides both RS-232 serial command control and contact closure GIPO control in a single unit. Use either serial control, contact control or both to achieve maximum remote control of your A/C power switching applications.

Serial control uses a simple command line interface (CLI) to operate the outlets and set all user programmable features. Login to the CLI is password protected, with multiple users, each with independently controllable rights to administrative functions and individual outlets. Users only see and can control the outlets that you authorize.

Each outlet can be controlled ON, OFF, or Cycled for a programmable time. Cycle can be either power down for Reboot, or power up.

Outlets can be grouped together for simultaneous function, with programmable delay set to avoid excessive inrush on startup. Each outlet can also be programmed with a unique name, startup condition, and contact closure operation parameters.

Command Line Example


SBB v1.00.63

User Name: admin
Password: *****

SBB> get all
Outlets 1 File_Server On
  2 Email_Server On
  3 VPN_Server On
  4 DNS_Server On
  5 Firewall On
  6 SQL_Server On
  7 Web_Server On
  8 VOIP_Server On
OK
SBB> set outlet 1 off
OK
SBB> set outlet 2 off
OK
SBB> logout
Goodbye
User Name: david
Password: *****

SBB> get all
Outlets: 1 File_Server Off
  2 Email_Server Off
OK
SBB>

Contact Closure Control


If you already have a remote control, SCADA, RDU or GPIO system, you can add A/C power switching with these rack mounted power strips.

Link Serial iBootBars to your own command and control system for your custom power control requirements. Setup allows contact open or closed to be defined as Power On or Off, and initial startup condition of the outlets.

Spring loaded connectors make it easy to tie the Serial iBootBar to your digital input controls.

contact closure gpio control for rack mounted remote power control serial ibootbar
remote control power strip. Model sBB-N15.  Serial and contact closure control of 8 outlets
Need Web/Telnet/SNMP Control? Click Here
Operation
8 Independently Controllable Outlets
The Serial iBootBar (sBB) series is designed to provide power distribution and remote power control.  Each sBB allows eight outlets to be independently switched on and off for reboot, energy management and security.  The sBB has many features to make the management of power distribution simple and cost effective
Serial RS-232 Control
RS-232 serial control allows for direct control of the sBB outlets, and complete setup of all parameters. Simple Command Line Interface uses clear language commands for all setup and control functions.  View Command List
Contact Closure Control
Each outlet is associated with a discrete input that can be connected to a physical switch or relay.  Changing the state of the input will operate the outlet.  Outlets are individually configurable for On and Off state relative to contact closed or open.
Multi-User
Assign permissions to each user for outlets and configuration. Users see only outlets assigned
Current Sensing and Alarms
Know when critical power conditions occur and take immediate action.
North American and
International Versions
115 VAC with N. American cords and plugs.
100-240VAC with IEC connections
Multiple users with assigned rights and simultaneous control
Up to 16 users can be assigned administrator or user only rights, plus access to specific outlets and groups.  Users only see the outlets and groups they are assigned to.
Group and Stagger
Combine any outlets into logical groups and managed together.  Power up Delay Timer prevents units from powering up simultaneously and overwhelming the current capacity.
Features
8 Independently Controllable Outlets
The Serial iBootBar (sBB) series is designed to provide power distribution and remote power control.  Each sBB allows eight outlets to be independently switched on and off for reboot, energy management and security.  The sBB has many features to make the management of power distribution simple and cost effective
Serial RS-232 Control
RS-232 serial control allows for direct control of the sBB outlets, and complete setup of all parameters. Simple Command Line Interface uses clear language commands for all setup and control functions.  View Command List
Contact Closure Control
Each outlet is associated with a discrete input that can be connected to a physical switch or relay.  Changing the state of the input will operate the outlet.  Outlets are individually configurable for On and Off state relative to contact closed or open.
Multi-User
Assign permissions to each user for outlets and configuration. Users see only outlets assigned
Current Sensing and Alarms
Know when critical power conditions occur and take immediate action.
North American and
International Versions
115 VAC with N. American cords and plugs.
100-240VAC with IEC connections
Multiple users with assigned rights and simultaneous control
Up to 16 users can be assigned administrator or user only rights, plus access to specific outlets and groups.  Users only see the outlets and groups they are assigned to.
Group and Stagger
Combine any outlets into logical groups and managed together.  Power up Delay Timer prevents units from powering up simultaneously and overwhelming the current capacity.
Specifications
PHYSICAL:
Height: 1U 1.75 in (4.5 cm)
Width: 19.0 in (48.25 cm)
Depth: 6.00 in (15.25 cm)
Weight: 7 lbs (3.25 Kg)
Temperature  
Operating: 0 to 40 o C
Storage: -10 to 85 o C
Relative Humidity 0 to 95% Non-Condensing
A/C INPUT
N15 Model NEMA 5-15 Linecord 115VAC
15 Amps combined total switched per Linecord
Supplied with NEMA 5-15 Linecord, attached
C10 Model IEC320 C14 Receptacle 100-240VAC
10 Amps total at 240VAC Max per Linecord
Supplied with IEC320 C13 to CEE7 (SHUCO) Linecord
CONTACT INPUTS
Two Terminals for each outlet control. AWG 30 to 18. Common Ground.
User Selectable Contacts Closed are Power On or Off.
SERIAL PORT
D9 Serial, configured as DCE. to 115.2Kbps
SWITCHED OUTLETS
N15 Model 8 x NEMA 5-15 Receptacle,
12 Amps Max per Receptacle, 15 Amps Max Total per Linecord
C10 Model 8 x IEC 320-C13
10 Amps Max per Receptacle, 10 Amps Max Total per Linecord
COMPLIANCE
UL / cUL Listed
CE Marked
RoHS / WEEE Compliant
FCC Part 15 Class B
Support
Tools for Serial BootBar Users
Standard Resources
Operations Manuals
Installation and Operations Instructions
User Resources
Catalog Sheet
iBootBar sales brochure
Upgrade Resources
Latest Version
sBB_upg_1.1 Incl. Upgrade Utility, Manual
Call
Upgrade Procedures
Instruction .pdf Included with complete package
Call
Special Purpose Versions
On Request
Custom, Private Label and OEM versions available.  
|
|
|
|
|
|
|
|
|
|


COPYRIGHT © Dataprobe, Inc.

1B Pearl Court, Allendale NJ 07401    Tel: 201-934-9944 / 800-436-3284